| S (D) BW | F | 50 | kVA |
| Samfurin samfurin | Lambar da aka samo | Ƙarfin da aka ƙima | Na'urar iya aiki |
| S: mataki uku D: mataki ɗaya B: nau'in diyya W: Mai sarrafa ƙarfin lantarki | F: yanayin raba C: Nau'in LCD S: fitarwa ta hanyar wucewa | 50 100 ... 1800 | kVA |
Ya kamata a yi amfani da na'urar sarrafa wutar lantarki a cikin gida, kuma yanayin amfani na yau da kullun kamar haka:
● Yanayin zafi: -5°C~+ 40°C
●Tsawon tsayi: tsayin da bai wuce mita 1000 ba
●Danshin da ya dace: ≤90%(20°C)
●Yanayin shigarwa: wurin shigarwa zai kasance babu iskar gas, tururi, ma'ajiyar sinadarai, ƙura, datti da sauran abubuwan fashewa da narkarwa waɗanda ke shafar rufin mai kula da wutar lantarki sosai.
● Inda sharuɗɗan musamman na amfani waɗanda ba su cika tanade-tanaden da ke sama ba, sashen mai amfani zai ƙayyade su ta hanyar tattaunawa da kamfaninmu.
Tare da aikin jinkirin taya
Idan yanayin daidaita ƙarfin lantarki yana aiki, danna maɓallin daidaita ƙarfin lantarki sannan ka daidaita mai daidaita ƙarfin lantarki zuwa ƙimar ƙimar ƙarfin lantarki mai ɗorewa (na ƴan daƙiƙa) kafin a sami na'urar samar da wutar lantarki ta fitarwa.
Kariyar ƙarfin lantarki da aikin ƙararrawa daga fitarwa
A yanayin daidaita ƙarfin lantarki, lokacin da ƙarfin shigarwa ya wuce kewayon ƙarfin shigarwa (304V ~ 456V) ko wasu dalilai suka sa ƙarfin fitarwa na mai sarrafa ƙarfin lantarki ya wuce ƙarfin lantarki (426V ± 7V), mai sarrafa wutar lantarki zai yanke wutar lantarki da ƙararrawa, kuma ya ci gaba da aikinsa ta atomatik lokacin da ƙarfin fitarwa ya ragu. Yana da aikinKariyar jerin matakai, idan layin shigarwar matakai uku ya yi kuskure ko ya karye, na'urar kariya za ta iya aiki ta yanke wutar lantarki ba tare da fitarwa ba. (tDole ne a gabatar da wannan fasalin a gaba).
An nuna ƙayyadaddun samfura da manyan alamun fasaha a cikin Tebur 1.
| Nau'i (Tebur 1) | Ƙarfin da aka ƙima kVA | Fitowar wutar lantarki A | Lambar mataki | Voltagearfin shigarwa V | Ƙarfin fitarwa V | Daidaiton daidaita ƙarfin lantarki | Kariyar ƙarfin lantarki V | Jure ƙarfin lantarki | Juriyar Rufi MΩ | Inganci | Mitar aiki Hz |
| SBW-20 | 20 | 31 | mataki uku | 304~456 | 380 | ±3% | 426±7 | 2000V 1min Babu fashewa | ≥5 | ≥97% | 50~60 |
| SBW-30 | 30 | 46 | |||||||||
| SBW-50 | 50 | 76 | |||||||||
| SBW-100 | 100 | 152 | |||||||||
| SBW-180 | 180 | 273 | |||||||||
| SBW-225 | 225 | 342 | |||||||||
| SBW-320 | 320 | 487 | |||||||||
| SBW-400 | 400 | 606 | |||||||||
| SBW-600 | 600 | 910 | |||||||||
| SBW-800 | 800 | 1212 | |||||||||
| SBW-1000 | 1000 | 1515 | |||||||||
| SBW-1200 | 1200 | 1818 | |||||||||
| SBW-1800 | 1800 | 2700 | |||||||||
| DBW-20 | 20 | 91 | mataki ɗaya | 176~264 | 220 | ±3% | 246±4 | 2000V 1min Babu fashewa | |||
| DBW-30 | 30 | 137 | |||||||||
| DBW-50 | 50 | 228 | |||||||||
| DBW-100 | 100 | 455 |
Girman zane (Duba tebur na 2)
| Samfuri (Tebur 2) | Girman zane (A×B×H)mm | Adadin wuraren rufewa |
| SBW-20~50kVA | 800×570×1270 | 1 |
| SBW-75~100kVA | 850×620×1370 | 1 |
| SBW-150~200kVA | 1000 × 700 × 1500 | 1 |
| SBW-250kVA | 1050×800×1600 | 1 |
| SBW-300kVA | 1100×850×1800 | 1 |
| SBW-400kVA | 1200×950×2050 | 1 |
| SBW-500~600kVA | 1100 × 1300 × 2100 | 1 |
| SBW-800~1200kVA | 1000 × 1230 × 2050 | 3 |
| SBW-1800kVA | 1200 × 900 × 1900 | 4 |
| DBW-20~50kVA | 800×570×1270 | 1 |
| DBW-100kVA | 850×620×1370 | 1 |
● Lokacin yin oda, ya kamata a bayyana samfurin samfurin, ƙarfin aiki, ƙarfin fitarwa mai ƙima, kewayon ƙarfin shigarwa, daidaiton daidaita ƙarfin lantarki, nisan shigarwar wutar lantarki (fitarwa) da sauran yanayin aiki.
● Idan kuna da wasu buƙatu na musamman, da fatan za a tuntuɓi sashen fasaha namu.